Cedar Rapids Free Classifieds and Ads   >   Industrial Equipment   >   Cedar Rapids District   >   Food Restaurant and Meat Processing   >   New oscilloscope leader ls 8022 20 mhz - scope

New oscilloscope leader ls 8022 20 mhz - scope


New oscilloscope leader ls 8022 20 mhz - scope
* High Sensitivity (1 mV/div)
* Withstands up to 400 V dc + ac Peak Inputs
* Level Lock and Alternate Triggering
* Dedicated TV-V and H Sync Separators
* 10 ns/div Maximum Sweep Speed
The LS 8022 20-MHz 2-Channel Oscilloscope is an economical choice for high stability and reliability. The oscilloscope is equipped with a variety of helpful functions (TV sync separator, variable holdoff, X-Y display mode) which makes this oscilloscope an ideal choice for production, field service and educational applications. The LS 8022 also conforms to International Standards for EMI, EMS and Safety.
An Excellent Addition to Your Lab Work Station
dc:5 mV to 5V/div:dc (ac:10 Hz) to 20 MHz
dc:1 mV to 2 mV/div:dc (ac:10 Hz) to 10 MHz
5 mV to 5V/div, approx. 17.5 ns
1 mV to 2 mV/div, approx. 35 ns
To 1/2.5 or less of panel indicated value
termination, 50 mV/div with 50 Ù
Balanced point variation ? 1 div
DUAL:CHOP/ALT are auto set by time
When CHOP switch is pushed in, the
two traces are displayed in the CHOP
ADD: CH1 + CH2 algebraic addition
EXTERNAL HORIZONTAL DEFLECTION
NORM:+4%, X10 MAG:± 6% (10°C to
INTERNAL HORIZONTAL DEFLECTION
0.1 ?s to 0.5 s/div, 21 steps in 1-2-5
? 1/2.5 of panel indicated value
10 times (max speed time 10 ns/div)
CH1, CH2, LINE, EXT (CH1 & CH2 can
be selected only when the vertical
In ALT mode, if the TRIG ALT switch is
pushed in, it can be used for alternate
triggering of two different sources.
Auto:Sweeps run in the free mode
when no triggering input signal is
applied. (Applicable for repetitive
signals of frequency 50 Hz or over).
Normal:When no triggering signal is
applied, the trace is in the READY state
TV-V/TV-H are auto set by TIME/DIV
dc to 5 MHz: 0.5 div (EXT 0.1 V)
5 to 20 MHz: 1.5 div (EXT 0.2 V)
TV (video signal): 2.0 div (EXT 0.2 V)
components of lower than 10 Hz
HF-REJ:Attenuate signal components of
Satisfies the value of the above trigger
sensitivity plus 0.5 div (EXT: 0.05 V) for
(New oscilloscope leader ls 8022 20 mhz - scope is the responsibility of Lawrence Barrett)
Contact: lawrence-barrett@cedar--rapids.com (Lawrence Barrett) (actual email hidden)
Contact lawrence-barrett@cedar--rapids.com (Lawrence Barrett) for more information.

Flag any violation to moderator

Your flag message:




New oscilloscope leader ls 8022 20 mhz - scope