â— Power supply: 9V battery (ANSI/NEDA 1604A or IEC 6LR619V alkaline) â— Battery life: about 12 hours under the condition of 10mA â— Max.permitted voltage: 30V (between any two terminals or between any terminal and earth ground) â—ÂOperating temperature : 0℃ to 50℃ â— Operating relative humidity: ≤80% RH â— Storage temperature : ≤-10℃to 55℃ â—ÂRelative humidity for storage: ≤90% RH â—ÂSize: 200×100×40mm(with holster) â—ÂAccessories: operation instruction, a set ofCF-36 industrial test lead(with alligator clips attached to probes) â— Option: AC power-supply adapter (VCPS), industrial test lead(CF-31-A with probe clips) â—ÂSafety: certified as compliant to IEC1010 provisions(Safety standard issued by International Electro technical Commission) Output Performance Capabilities(applicable to temperature range form 18℃ to 28℃,within one year after calibration) Input Performance Capabilities(applicable to temperature range form 18℃ to 28℃,within one year after calibration) Notes: 1. When the battery voltage exceeds 6.8V, the max. load is 1KΩ at 20mA. When its voltage lies between 5.8V and 6.8V ,The max. load is 700Ω at 20mA. 2. Power supply range: 5 to 25VDC. 3. Temperature coefficient: ±0.005% of range per ℃ for the temperature ranges 5℃ to 18℃ and 28℃ to 40℃ All our Calibrators are provided one year warrantee by us from the date you make a purchase. An replacement or repairment will be provided by us for free when a faulty is developed within the warrantee. (Process calibrator VC15 is the responsibility of Savannah Wilkerson) |
Savannah_Wilkerson@cedar--rapids.com (Savannah Wilkerson)
for more information.