G779LHA-1. The G779 Universal Replacement Intermittent Pilot Ignition Control replaces many existing intermittent pilot controls made by various manufacturers. It is a safety control designed for indirect burner ignition and supervision. The G779 can be used with all gas-fired appliances with a maximum firing rate of 400,000 Btu/hr.
The G779 replaces existing intermittent pilot ignition controls with the following specifications:
• flame detection using flame rectification technology (ability of a flame to conduct and rectify current)
• integral or remote flame sensing
• non-100% lockout, 100% lockout, or 100% shutoff with continuous retry
• trial for ignition period greater than or equal to 25 seconds
• prepurge period less than 1 second
• pilot burners with flow rates of 1,500 Btu/hr or less
• operating with or without vent dampers